Product Details:
Payment & Shipping Terms:
|
Product Name: | UV Sterilizer | Flow Rate: | 1000 LPH |
---|---|---|---|
Inlet And Outlet Diameter: | 1/2 Inch | Power: | 25W |
Service Life Of The UV: | More Than 9000 Hours | Power Supply: | 380V/220V/110V 50Hz/60Hz |
Connection Mode: | Thread | Working Pressure: | 0.6Mpa |
Highlight: | ultraviolet water sterilizer,water uv sterilizer |
1000LPH Germicidal lamp UV Water Sterilizer For Residential Drinking Water Disinfection
Product features:
There are several advantages of using UV water filtration system rather than a chemical disinfection
solution
(such as chlorination):
1. No known toxic or significant nontoxic byproducts
2. No danger of overdosing
3. Does not require storage of hazardous material
4. Adds no smell to the final water product
5. Requires very little contact time
Working principle:
UV sterilizers work on the principle that special fluorescent UV lamps can effectively irradiate (kill)
microorganisms in aquarium water when they are exposed to this light. UV light, at a peak wavelength
of approximately 254
nanometers, alters the genetic material in the organism's nucleus and shortens its normal life cycle.
Theoretically, UV sterilizers can kill viruses, bacteria, algae, and protozoa with no residual effects.
However, the organisms
must be free-floating and travel through the UV sterilizer unit for the sterilizer to work. It has no effect on organisms
attached to
fish or rocks because they do not flow through the unit and cannot be exposed to the UV light.
What does a UV sterilizer do?
Ultraviolet sterilization (UV) is a process to eliminate biological contamination, namely parasite fungus
and
bacteria. Two types are commercially available, both in tube size. Generally the one containing a wet
bulb -at which the water passes directly past the UV bulb- is cheaper.
The other type available has a protective quartz tube around the bulb (dry bulb). The latter has the
advantage of
easier cleaning, since debris and slime will eventually settle on the bulb, or quartz surrounding. Both
work on
the same principle.
UV sterilization exposes the contaminants with a lethal dose of energy in the form of light. The UV
light will alter
the DNA of the pathogens, by virtually gluing DNA molecules together. The changed cell structure
prevents the
organism from reproducing itself (sterilization), therefore eliminating it.
Application
1, Food, beverage, beer, edible oil, all kinds of canned goods, cold drinks products etc. using water
disinfection
2, Electrons industry ultra pure water, military camps, outdoor water supply system
3, Hospital, lab, high content causative agent waste water disinfection
4, Residents building, housing estate, office building, hotel, restaurant, waterworks disinfection
5,Aquatic product processing purification, shellfish purification, fish processing purification etc.
6, Town wastewater sterilization
7, Swimming pool, other entertainment water sterilization
8, Thermal power, industrial cooling water, central air conditioner system cooling water disinfection
9, Biology, chemical pharmaceutical, cosmetic using water disinfection
10, Seawater, freshwater seeding, aquaculture water
11,Agricultural water, greenhouse water, irrigation disinfection etc.
Optimal service condition:
As UV is a short- wavelength light wave, it has low radiant energy and weak penetrating power and
can only kill the microorganisms it directly radiates on. Therefore, in order to enhance the bacteria-killing efficiency and ensure the security of drinking water, the incoming water into the sterilizer must meet the following standard, (and if exceeding the following standard, the killing efficiency may be affected).
Total iron content |
Less than 0.3ppm(0.3mg/L) |
H2S |
Less than 0.05ppm(0.05mg/L) |
Total suspended matter |
Less than 10 mg/L |
Manganese content |
Less than 0.05 mg/L |
Water hardness |
Less than 120 mg/L |
Chroma |
Less than 15centigrade |
Water Temp. |
5-60Centigrade |
PH value |
6.5-8 |
Interface type |
flange or thread |
Technical Parameters:
model |
capacity |
Power |
inlet-outlet |
reactor |
panel |
Anchor |
G weight |
|
m³/hour |
watt |
mm |
L×W×H |
cm |
screw |
Kg |
YLCn-005 |
0.3 |
16 |
1/2″ |
30×6×11 |
without |
without |
5 |
YLCn-008 |
1 |
25 |
1/2″ |
47×6.3×11 |
without |
without |
10 |
YLCn-050 |
2 |
40 |
1″ |
100×9×20 |
Φ8.9×25 (d×L) |
69×4×Φ1 |
25 |
YLCn-150 |
6 |
80 |
1+1/4″ |
100×11×23 |
|
69×4×Φ1 |
30 |
YLCn-200 |
8 |
120 |
1+1/2″ |
100×15.9×30 |
Φ8.9×45 (d×L) |
69×7×Φ1 |
35 |
YLCn-300 |
12 |
160 |
2″ |
100×15.9×32 |
|
69×7×Φ1 |
40 |
YLC-050 |
2 |
40 |
DN25/1″ |
100×8.9×30 |
25×30×12 (W×H×D) |
60×4×Φ1 |
45 |
YLC-150 |
6 |
80 |
DN32/11/4″ |
100×10.8×30 |
|
60×4×Φ1 |
50 |
YLC-200 |
8 |
120 |
DN40/11/2″ |
100×15.9×40 |
|
60×7×Φ1 |
60 |
YLC-300 |
12 |
160 |
DN50/2″ |
100×15.9×40 |
|
60×7×Φ1 |
70 |
YLC-360 |
15 |
200 |
DN65/21/2″ |
100×15.9×40 |
|
60×7×Φ1 |
120 |
YLC-500 |
20 |
240 |
DN65/21/2″ |
100×21.9×50 |
|
60×11×Φ1.2 |
130 |
YLC-600 |
25 |
280 |
DN80/3″ |
100×21.9×50 |
|
60×11×Φ1.2 |
140 |
YLC-700 |
30 |
320 |
DN100/4″ |
100×21.9×50 |
|
60×11×Φ1.2 |
150 |
YLC-1000 |
40 |
360 |
DN100/4″ |
100×21.9×50 |
|
60×11×Φ1.2 |
160 |
YLC-1200 |
50 |
400 |
DN125/5″ |
100×21.9×50 |
|
60×11×Φ1.2 |
180 |
YLC-1500 |
60 |
420 |
DN150/6″ |
170×27.3×57 |
|
120×16×Φ1.4 |
210 |
YLC-2000 |
80 |
560 |
DN150/6″ |
170×27.3×57 |
|
120×16×Φ1.4 |
220 |
YLC-2500 |
100 |
700 |
DN150/6″ |
170×27.3×57 |
60×128×30 (W×H×D) |
120×16×Φ1.4 |
275 |
YLC-3000 |
125 |
840 |
DN150/6″ |
170×27.3×57 |
|
120×16×Φ1.4 |
300 |
YLC-4000 |
150 |
1120 |
DN200/8″ |
173×32.5×65 |
|
120×20×Φ1.6 |
325 |
YLC-5000 |
200 |
1400 |
DN200/8″ |
173×37.7×72 |
|
120×22×Φ1.6 |
350 |
YLC-7000 |
300 |
2100 |
DN250/10″ |
175×42.6×80 |
|
120×24×Φ2.0 |
400 |
YLC-10K |
400 |
2520 |
DN250/10″ |
176×52.9×95 |
60×150×40 (W×H×D) |
120×22×Φ2.2 |
475 |
YLC-15K |
600 |
3080 |
DN300/12″ |
176×78×110 |
|
120×32×Φ2.4 |
600 |
YLC-20K |
800 |
3920 |
DN350/14″ |
Designated |
Designated |
Designated |
Designated |
YLC-25K |
1000 |
4760 |
DN350/14″ |
Designated |
Designated |
Designated |
Designated |
FAQ:
Q. Are UV sterilizers a good replacement for biological and mechanical filtration?
A. NO. UV sterilizers are not a replacement for good biological and mechanical filtration, regular water changes, or proper control of the nitrogen cycle.
Q.What is the proper maintenance schedule for UV sterilizers?
A.The quartz sleeve will need to be checked monthly and removed and cleaned with rubbing alcohol. Some larger UV sterilizers have wiper mechanism units installed for easier maintenance.
Products show:
Contact Person: Miss.
Tel: 10-65569770
Fax: 86-10-8563-2312
Portable Ultrasonic Flow Meter, High Reliability Waterproof Flowmeter TUF-2000F
High Accuracy Portable Flowmeter , Online Ultrasonic Flow Meter TUF-2000S
TUF-2000H Handheld Ultrasonic Flow Meter, Non-Intrusive Measuring Flowemeter
Automatic Read Residential Plastic Multi Jet Water Meter With PDA/ Fixed Network
Plastic Nylon Multi Jet Super Dry Cold Water Meter ISO4064 Class B
Brass Multi Jet Domestic Water Meter Hot With End Flange / BSP LXSR-50E
YSI Pro20 Dissolved Oxygen METER and Temperature Handheld 6050020
Single Jet Water Meter Dry Dial LXSC-15D For Resident, Remote Reading Water Meter
Resident Rotary Domestic Single Jet Water Meter Anti Magnetic For Hot Water