Product Details:
Payment & Shipping Terms:
|
Product Name: | UV Water Sterilizer | Flow Rate: | 40m3/h |
---|---|---|---|
Inlet And Outlet Diameter: | DN100mm/4 Inch | Power: | 360W |
Service Life Of The UV: | 9000 Hours | Power Supply: | 220V/380V, 50HZ/60HZ |
Connection Mode: | Flange | Working Pressure: | 0.6Mpa |
Highlight: | ultraviolet water sterilizer,water uv sterilizer |
Vertical 40TPH Water Disinfection UV Water Sterilizer For Poultry Livestock Farming
Advantages
Usages and Advantages
· Effective: Virtually all microorganisms are susceptible to UV disinfection
· Automatic: Continuous or intermittent disinfection without special attention
· Fast: Water is ready for consumption as soon as it leaves the cell
· Easy: Simple installation and maintenance. Minimum space requirement
· Safe: No danger or way of overdosing, no addition of hazardous chemicals
· Versatile: Capacities available from 2 to 80 gallons per minute
· Economical: Hundreds of gallons of water can be purified for a few cents per day
· No Chemicals: No chlorine taste or corrosion problems
How is a UV sterilizer installed?
The UV sterilizer should be the last piece of equipment in the system before the water is returned to the
aquarium. It should be preceded by the biological and mechanical filters, and any chemical filter or heat
exchanger in the
system. Follow the manufacturer's directions on installation. Most units use hose barb connectors to attach to
the appropriate water pump or are designed to allow add on connectors as a PVC slip fit or hose barb
attachment.
What is the proper maintenance schedule for UV sterilizers?
The quartz sleeve will need to be checked monthly and removed and cleaned with rubbing alcohol. Some larger
UV sterilizers have wiper mechanism units installed for easier maintenance.
For most units, the UV bulb will need to be replaced after 6 months of continuous use, however, this time may
vary so be sure to follow the manufacturer's recommendations. When installing or changing a bulb, never look
directly at the bulb when the unit is turned on. Doing so can result in permanent damage to your eyes.
(The damage can occur without you feeling any discomfort.)
Working principle:
The UV sterilizer utilizes a germicidal fluorescent lamp that produces light at a wavelength of approximately 254
nanometers (2537 Angstroms). The water with the bacteria/algae passes over the bulb (or around the bulb if a
quartz sleeve is used) and is irradiated with this wavelength. As the light penetrates the bacteria/algae, it
mutates the DNA (genetic material), preventing growth/multiplication of the organism.
Application
Ultraviolet water purification systems are used in many applications that includes home/residential (both well
water and municipal water supplies), commercial, and industrial. Here is a list of several applications where the
power of UV water sterilizers are commonly used to treat and protect the water supply for contaminates such
as bacteria and viruses. UV systems applications include private wells, campgrounds, hotels, bottlers,
aquaculture,
hospitals, food, cottages, restaurants, breweries, water systems, laboratories, marine, pharmaceutical, dairies
and many other applications.
Optimal service condition:
As UV is a short- wavelength light wave, it has low radiant energy and weak penetrating power and can
only kill the microorganisms it directly radiates on. Therefore, in order to enhance the bacteria-killing
efficiency and ensure the security of drinking water, the incoming water into the sterilizer must meet
the following standard, (and if exceeding the following standard, the killing efficiency may be affected).
Total iron content |
Less than 0.3ppm(0.3mg/L) |
H2S |
Less than 0.05ppm(0.05mg/L) |
Total suspended matter |
Less than 10 mg/L |
Manganese content |
Less than 0.05 mg/L |
Water hardness |
Less than 120 mg/L |
Chroma |
Less than 15centigrade |
Water Temp. |
5-60Centigrade |
PH value |
6.5-8 |
Interface type |
flange or thread |
Technical Parameters:
model |
capacity |
Power |
inlet-outlet |
reactor |
panel |
Anchor |
G weight |
|
m³/hour |
watt |
mm |
L×W×H |
cm |
screw |
Kg |
YLCn-005 |
0.3 |
16 |
1/2″ |
30×6×11 |
without |
without |
5 |
YLCn-008 |
1 |
25 |
1/2″ |
47×6.3×11 |
without |
without |
10 |
YLCn-050 |
2 |
40 |
1″ |
100×9×20 |
Φ8.9×25 (d×L) |
69×4×Φ1 |
25 |
YLCn-150 |
6 |
80 |
1+1/4″ |
100×11×23 |
|
69×4×Φ1 |
30 |
YLCn-200 |
8 |
120 |
1+1/2″ |
100×15.9×30 |
Φ8.9×45 (d×L) |
69×7×Φ1 |
35 |
YLCn-300 |
12 |
160 |
2″ |
100×15.9×32 |
|
69×7×Φ1 |
40 |
YLC-050 |
2 |
40 |
DN25/1″ |
100×8.9×30 |
25×30×12 (W×H×D) |
60×4×Φ1 |
45 |
YLC-150 |
6 |
80 |
DN32/11/4″ |
100×10.8×30 |
|
60×4×Φ1 |
50 |
YLC-200 |
8 |
120 |
DN40/11/2″ |
100×15.9×40 |
|
60×7×Φ1 |
60 |
YLC-300 |
12 |
160 |
DN50/2″ |
100×15.9×40 |
|
60×7×Φ1 |
70 |
YLC-360 |
15 |
200 |
DN65/21/2″ |
100×15.9×40 |
|
60×7×Φ1 |
120 |
YLC-500 |
20 |
240 |
DN65/21/2″ |
100×21.9×50 |
|
60×11×Φ1.2 |
130 |
YLC-600 |
25 |
280 |
DN80/3″ |
100×21.9×50 |
|
60×11×Φ1.2 |
140 |
YLC-700 |
30 |
320 |
DN100/4″ |
100×21.9×50 |
|
60×11×Φ1.2 |
150 |
YLC-1000 |
40 |
360 |
DN100/4″ |
100×21.9×50 |
|
60×11×Φ1.2 |
160 |
YLC-1200 |
50 |
400 |
DN125/5″ |
100×21.9×50 |
|
60×11×Φ1.2 |
180 |
YLC-1500 |
60 |
420 |
DN150/6″ |
170×27.3×57 |
|
120×16×Φ1.4 |
210 |
YLC-2000 |
80 |
560 |
DN150/6″ |
170×27.3×57 |
|
120×16×Φ1.4 |
220 |
YLC-2500 |
100 |
700 |
DN150/6″ |
170×27.3×57 |
60×128×30 (W×H×D) |
120×16×Φ1.4 |
275 |
YLC-3000 |
125 |
840 |
DN150/6″ |
170×27.3×57 |
|
120×16×Φ1.4 |
300 |
YLC-4000 |
150 |
1120 |
DN200/8″ |
173×32.5×65 |
|
120×20×Φ1.6 |
325 |
YLC-5000 |
200 |
1400 |
DN200/8″ |
173×37.7×72 |
|
120×22×Φ1.6 |
350 |
YLC-7000 |
300 |
2100 |
DN250/10″ |
175×42.6×80 |
|
120×24×Φ2.0 |
400 |
YLC-10K |
400 |
2520 |
DN250/10″ |
176×52.9×95 |
60×150×40 (W×H×D) |
120×22×Φ2.2 |
475 |
YLC-15K |
600 |
3080 |
DN300/12″ |
176×78×110 |
|
120×32×Φ2.4 |
600 |
YLC-20K |
800 |
3920 |
DN350/14″ |
Designated |
Designated |
Designated |
Designated |
YLC-25K |
1000 |
4760 |
DN350/14″ |
Designated |
Designated |
Designated |
Designated |
FAQ:
Q. Are UV sterilizers a good replacement for biological and mechanical filtration?
A. NO. UV sterilizers are not a replacement for good biological and mechanical filtration, regular water changes,
or proper c
ontrol of the nitrogen cycle.
Q.What is the proper maintenance schedule for UV sterilizers?
A.The quartz sleeve will need to be checked monthly and removed and cleaned with rubbing alcohol.
Some
larger UV sterilizers have wiper mechanism units installed for easier maintenance.
Contact Person: Miss.
Tel: 10-65569770
Fax: 86-10-8563-2312
Portable Ultrasonic Flow Meter, High Reliability Waterproof Flowmeter TUF-2000F
High Accuracy Portable Flowmeter , Online Ultrasonic Flow Meter TUF-2000S
TUF-2000H Handheld Ultrasonic Flow Meter, Non-Intrusive Measuring Flowemeter
Automatic Read Residential Plastic Multi Jet Water Meter With PDA/ Fixed Network
Plastic Nylon Multi Jet Super Dry Cold Water Meter ISO4064 Class B
Brass Multi Jet Domestic Water Meter Hot With End Flange / BSP LXSR-50E
YSI Pro20 Dissolved Oxygen METER and Temperature Handheld 6050020
Single Jet Water Meter Dry Dial LXSC-15D For Resident, Remote Reading Water Meter
Resident Rotary Domestic Single Jet Water Meter Anti Magnetic For Hot Water