M552 Combined sidewall probe | |||
Applications | |||
Have a good performance of stratum Lithology acquisition, strata division, resistivity, porosity and volume density determination so that makes it a incompensible part of the series probes. It can valuate the radiate minerals content such as K and U, tell radiate minerals from non-radiate ones and also can serves as part of other methods. | |||
Specifications | |||
Measured parameters: double-spaced compensated density (DsCD), Natural Gamma, Three directionlaterolog, Caliper and spontaneous potential | |||
Data transmitter: 8-bit serial output | ![]() | ||
Work environment: -10℃ to 70℃ | |||
Dimensions:Ф50×2950mm (divided to two segments) | |||
Probe weight: ≤28 Kg, | |||
Pressurization: less than 20Mpa | |||
DsCD (double-spaced compensate density log) | |||
The source is based on oriented-emitting, and explorer uses long- or short-spaced oriented receiver which is wall-sticking can reduce affect borehole type to the density measurement. | |||
Work source strength: 100mCi137Cs radioisotopes. | |||
Short spacing: 200mm, Long spacing: 350mm | |||
Glimmers body: Nal(T1), Ф23×40mm | |||
Photomultiplier Tube: GDB23 | |||
Counting range: 0 to 32000cps | |||
Measurement density range: 1 to 4g/cm3 | |||
Measurement relative error: 5% | |||
Stability: work a continual 4-hour (5μCi or C s137 source), and the output changes less than 5% | |||
Natural Gamma logging | |||
Glimmers body: NaI(T1), Φ23×60mm | |||
Photomultiplier Tube: GDB23 | |||
Measurement range: > 30Kev γ-rays | |||
Counting range: 0 to 32000cps | |||
Stability: be able to work a continual 4-hour, and the output change no more than 3.5%(an average of 100 data set). | |||
Trace-interval disturbance: Values the source-loaded traces can disturb the natural ones are no more than 0.5%. | |||
Three-lateral Resistivity laterolog | |||
Range of measurement: 0 to 2kΩ | |||
Scaling accuracy error: <5% | |||
Stability: can work a continual 4-hour, and its output changes no more than 5%. | |||
Main electrode length: 25mm, electrodes full length is 455mm | |||
Caliper logging | |||
phole device controls the downhole probe, make it instantly fold or unfold the legs. | |||
Measurement range: φ50mm to φ300mm | |||
Measure sensitivity: 0.5mm | |||
Scale accuracy error: <3% | |||
Spontaneous potential | |||
Measuring range: -2V to +2V | |||
Measuring accuracy: ±2.5 mv | |||
JCS-1/SJSC-1 Digital inclination probe | |||
Vertex angle range: 0 to 60° | ![]() | ||
Vertex angle accuracy: ≤0.1° | |||
Azimuth range: 0 to 360° | |||
Azimuth accuracy: if 2°< vertex angle≤3°,±4°; and if vertex angle > 3°, ±2°. | |||
Work temperature: 0 to 80℃ | |||
Dimensions: Φ45×1200mm | |||
Weight: ≤ 4Kg (weight-gained bar is 5Kg) 6.36 KG (3000 meters) | |||
Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m) | |||
Main performance: an axis-oriented system of point-by-point or continual measuring, digital output, easy to use and reliability. | |||
S524/SS524 Acoustic wave probe | |||
Applications | |||
It is a non-oriented measurement of single-source double-receiver.Determination including lithology, strata porosity, gas-contained strata, and fault detection. Make use of any other log resources, can ascertain the degree of moisture content of strata, and if execute the acoustic logging, we may check out the cement glue quality of borehole tube. | |||
Measurement range: 125 to 555μs/m Receiving nearby: 0 to 833.3312μs/M Source intervals: 106ms Source wave frequency: 20KHz±5KHz Scale accuracy: ±5μs/M Source spacing: 0.5M to 0.7M Spacing : 0.2M Transmission mode: 8-bit digital data Environment temperature: -10℃ to 70℃ Dimensions: φ50×2240mm, φ55×1861mm (3000m) Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m) Weight: 11.2kg, 13kg (3000m) | ![]() | ||
M433/SM433 Double-density probe | |||
Source intensity: 30mCi137Cs radioisotopes,Long/short-spaced natural gamma probes are all be used. | |||
Scintillating material: Nal(T1), Φ23×60m Photomultiplier Tube: GDB23 Count range: 0 to 32000cps Long spacing: between 400 to 500mm adjustable. Short spacing: between 250 to 350mm adjustable Density measuring range: 1 to 4g/cm3 Natural gamma measuring range: 1 to 10000API Dimensions: Φ45×1750mm,Φ50×1804mm(3000m) Pressurization:≤ 20Mpa, ≤ 30Mpa (3000m) Digital transmitter: 8-bit serial outputWeight: 8.4kg, 10.7 kg(3000m) | ![]() | ||
Applications | |||
It is specially apply for exploring the dry borehole. The method that compensated density can divide the strata, determine the porosity of rock and density of volume. Naturalγis applied to identify lithology, locate the strata, estimate the sludge content, tell the rock strata from the shale one. Evaluate the radiate minerals that have a content of potash, anhydrite or U, and find out the non-radiate minerals such as salty rock, non-water gypsum and so on. | |||
W422/SW422 Temperature and liquid resistivity combined probe | |||
Measuring range: -10℃ to 100℃ | |||
Stability: the output changes of no more than 3% for 4 hours of continuous operation under the same | |||
conditions | |||
Applications: locate the aquifer bed or thermal spring in the geothermal survey; search for petroleum and gases | |||
X411/SX411 Three-lateral direction resistivity laterolog probe | |||
Measuring range: 0 to 10KΩm Output signal: 0 to 9V DC Work temperature : -10℃ to 60℃ Dimensions:ф40×1416mm,ф50×1416mm(3000m)Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m) Weight: 6.6kg,7.2kg (3000m) | ![]() | ||
Application: determines the resistivity of rock strata. | |||
H411/SH411 Magnetic susceptibility probe | |||
Measuring range: 1 to 10000×10-4 SI Output signal: 0 to 9V DC voltage Scale accuracy: ≤5% Stability error: ≤10% Work temperature: -10℃ to 60℃ Dimensions: φ45×1200mm,φ48.5×1377mm(3000m) Pressurization: ≤ 20Mpa, ≤ 30Mpa (3000m) Weight: 5.6 kg; 6.9kg (3000m) Application: seeking for magnetic iron ores | |||
J411/SJ411 Caliper probe | |||
Measuring range: 40mm to 300mm Output signals: 0 to 9V DC voltage Sensitivity: 1mm Work temperature: -10℃ to 60℃ Dimensions: φ40×1320mm,φ50×1324mm(3000m) Pressurization:≤ 20Mpa, ≤ 30Mpa (3000m) Weight; 6.6kg,7.2kg (3000m) | ![]() | ||
Applications: check the integrity of well and provide additional information to help. | |||
J511/SJ511 Big-hole caliper probe | |||
Measuring range: 75mm to 700mm Output signal: 0 to 9V DC voltage Sensitivity: 2 mm Dimensions: φ40×1620mm,φ50×1324mm(3000m) Pressurization:≤ 20Mpa, ≤ 30Mpa (3000m) Weight: 6.5kg, 7.2kg (3000m) | ![]() | ||
Application: used for big-bore logging | |||
NP442 Multi-channel spectrum probe | |||
Measuring range: 0.3Mev to 3Mev full differential spectrum | |||
Resolution: standard-source C137s(0.66Mev) ≤15% Time count range: 4″,12″,20″,28″,36 by manual Integrated nonlinear: ≤2% Differential nonlinear: ≤±5% Dead time: < 50μs Stable spectrum source: 133Ba, 5μCi Pressurization: less than 20Mpa | |||
Dimensions: Main probe: φ45×1330mm, Probe 1st: φ40×800mm,Probe 2nd: φ65×800mm | |||
Stability: the biggest error is less than 5%, which the average value of each data set comparing with the total average. | |||
Application: in research of uranium ore, divide the strata, and tell the oil stratum from the water zone. | |||
Z422/SZ422 Neutron combined probe | |||
Measuring parameters: N-N, natural gamma Neutron activated source: 241Am-9Be, 1Ci Counting range: 0 to 10000cps Proportional counter : 39He Natural gamma: Scintillating material: Nal(T1), Φ23×60m Photomultiplier tube type: GDB23 Measuring range: >30Kev gamma ray Counting range: 0 to 32000cps Work temperature:-10℃ to +60℃ Dimensions: φ45×2050mm,φ50×2000mm (3000m) Pressurization:≤ 20Mpa, ≤ 30Mpa (3000m) Weight: 7.8kg, 8.6kg (3000m) | ![]() | ||
R411/SR411 Natural gamma probe | |||
Measurement parameter: nature gamma Dimensions: ф40mm×870mm;ф45mm×870mm (3000m) Pressurization: ≤ 20Mpa Digital transmission: 8 bits serial output Operating temperature: 0℃ to +60 ℃ Weight: 5.7 kg; 6.8 kg (3000m) Range: more than 30Kev Scintillator: NaI(Tl)、φ23×60mm Photomuitplier: GDB23 Counting range: 0 to 32000 cps | ![]() | ||
Contact Person: Miss.
Tel: 10-65569770
Fax: 86-10-8563-2312
Portable Ultrasonic Flow Meter, High Reliability Waterproof Flowmeter TUF-2000F
High Accuracy Portable Flowmeter , Online Ultrasonic Flow Meter TUF-2000S
TUF-2000H Handheld Ultrasonic Flow Meter, Non-Intrusive Measuring Flowemeter
Automatic Read Residential Plastic Multi Jet Water Meter With PDA/ Fixed Network
Plastic Nylon Multi Jet Super Dry Cold Water Meter ISO4064 Class B
Brass Multi Jet Domestic Water Meter Hot With End Flange / BSP LXSR-50E
YSI Pro20 Dissolved Oxygen METER and Temperature Handheld 6050020
Single Jet Water Meter Dry Dial LXSC-15D For Resident, Remote Reading Water Meter
Resident Rotary Domestic Single Jet Water Meter Anti Magnetic For Hot Water